HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

SAS HBA 406
Table 17-86 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Property name Property implementation
3 (Enclosure) for c-Class blade systems
ImpactedDomain
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the following
properties (indicated with *) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
17.4.16Enclosure Fan Status Changed to OK
Table 17-87 HPSAS_DeviceIndication: Enclosure Fan status changed to OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Fan status has changed from a
non-OK state to OK.
AlertingMangedElement WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 304