HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

SAS HBA 402
Table 17-84 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to OK
Property name Property implementation
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
17.4.14Enclosure Temperature Status Changed to Warning
Table 17-85 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Temperature sensor Status
changed to Warning Condition. This indicates the
enclosure temperature is above normal, otherwise
enclosure is still operating normally.
AlertingMangedElement WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 308
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName Name of the computer system generating the indication