HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

SAS HBA 395
Table 17-81 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name Property implementation
EventCategory 17 (Primary Storage Power)
ProbableCause 89 (Power Supply Failure)
ProbableCauseDescription Redundant Power Supply Status Changed to Non-
Redundant
ProviderVersion Provider version generating the indication, in the form:
major.minor.revision.build.
NetworkAddresses List of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
69 (Windows Server 2003 32-bit)
OSType
70 (Windows Server 2003 64-bit)
77 (Windows Server 2008 32-bit)
77 (Windows Server 2008 64-bit)
103 (Windows Server 2008 R2)
OSVersion The operating system version of the computer system
generating the indication in the following format:
major.minor.build
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames FailureDescription
VariableTypes 1 (String)
VariableValues Short Description of failure
In some cases, VariableValues can be N/A or “” (null).
3 (Enclosure) for c-Class blade systems
ImpactedDomain
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the following
properties (indicated with *) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists