HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

SAS HBA 394
Table 17-80 HPSAS_DeviceIndication: Logical Drive is in a degraded state
Property name Property implementation
BladeBay * HP_BladeCSLocation.LocationInformation[0]
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
17.4.10Power Supply Status Changed to Non Redundant
Table 17-81 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Subsystem status has
changed to non-redundant.
AlertingMangedElement WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 301
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Power Supply status Non-Redundant