HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
SAS HBA 392
Table 17-79 HPSAS_DeviceIndication: Logical Drive status ERROR
Property name Property implementation
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
• 3 (Enclosure) for c-Class blade systems
ImpactedDomain
• 4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the following
properties (indicated with *) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
17.4.9Logical Drive is in a Degraded State
Table 17-80 HPSAS_DeviceIndication: Logical Drive is in a degraded state
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A logical drive is in a degraded state. Device is still
servicing I/O, but redundancy may be degraded or
lost.
AlertingMangedElement WBEM Path of Storage Volume
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 103