HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

SAS HBA 391
17.4.8Logical Drive Status ERROR
Table 17-79 HPSAS_DeviceIndication: Logical Drive status ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A logical drive status has changed to Error.
AlertingMangedElement WBEM Path of Storage Volume
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 102
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Check for failed or removed physical drives.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Logical drive status Error
EventCategory 6 (Primary Storage)
ProbableCause 86 (Disk Failure)
ProbableCauseDescription Logical Drive Status Changed to Error
ProviderVersion Provider version generating the indication, in the form:
major.minor.revision.build.
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
69 (Windows Server 2003 32-bit)
OSType
70 (Windows Server 2003 64-bit)
77 (Windows Server 2008 32-bit)
77 (Windows Server 2008 64-bit)
103 (Windows Server 2008 R2)
OSVersion The operating system version of the computer system
generating the indication in the following format:
major.minor.build
SystemFirmwareVersion Firmware version of the computer system generating
the indication