HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

SAS HBA 387
Table 17-76 HPSAS_DeviceIndication: Physical Drive status REBUILDING
Property name Property implementation
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
HWFirmwareVersion Disk firmware version string
HWLogicalLocation Disk Location string
For example, Bay 3
HWManufacturer Disk Manufacturer string
HWSerialNumber Disk Serial Number
HP_DeviceIndication
DeviceModel Disk Model string
17.4.6Drive Status PREDICTIVE FAILURE
Table 17-77 HPSAS_DeviceIndication: Drive status PREDICTIVE FAILURE
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A physical drive status has changed to Predictive
Failure.
AlertingMangedElement WBEM Path of disk drive
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 204
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Replace drive immediately to avoid loss of data.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication