HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

SAS HBA 381
Table 17-73 HPSAS_DeviceIndication: SAS HBA in Error state
Property name Property implementation
HWLogicalLocation Controller Location string
For example, Slot 3
HWManufacturer Controller Manufacturer string
HWSerialNumber Controller Serial Number
HP_DeviceIndication
DeviceModel Controller Model string
17.4.3Physical Drive Status OK
Table 17-74 HPSAS_DeviceIndication: Physical Drive status OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication
Description A physical drive status has changed from non-OK to
OK.
AlertingMangedElement WBEM Path of disk drive
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 201
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions No action is recommended.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical Drive Status is now OK
EventCategory 6 (Primary Storage)
ProbableCause 1 (Other)
ProbableCauseDescription Physical Drive Status Changed to OK