HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

SAS HBA 377
Table 17-70 Class: HPSAS_DiskPhysicalPackageDiskDriveLocation (CIM_PhysicalElementLocation)
Property name Property implementation
Element HPSAS_DiskPhysicalPackage
PhysicalLocation HPSAS_DiskDriveLocation
17.3.70HPSAS_SCSIProtocolEndpointSCSIProtocolController
(Association)
Table 17-71 Class: HPSAS_SCSIProtocolEndpointSCSIProtocolController (CIM_SAPAvailableForElement)
Property name Property implementation
AvailableSAP HPSAS_SCSIProtocolEndpoint
ManagedElement HPSAS_SCSIProtocolController
17.4Supported indications
17.4.1SAS HBA Status OK
Table 17-72 HPSAS_DeviceIndication: SAS HBA status OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication
Description A SAS/SATA HBA status has changed from non-OK to
OK.
AlertingMangedElement WBEM Path of controller
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions No action is recommended.
SystemName Name of the computer system generating the indication