HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Smart Array 313
Table 15-136 HPSA_DeviceIndication: Enclosure Fan status changed to Failure
Property name Property implementation
EventID 306
ProviderName HP Smart Array
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Fan status Error.
EventCategory 24 (Primary Storage Cooling)
ProbableCause 94 (Fan failure)
ProbableCauseDescription Fan Failure
NetworkAddresses A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication.
• 69 (Windows Server 2003 32-bit)
OSType
• 70 (Windows Server 2003 64-bit)
• 76 (Windows Server 2008 32-bit)
• 77 (Windows Server 2008 64-bit)
• 103 (Windows Server 2008 R2)
OSVersion Operating system version of the computer system
generating the indication in the format,
major.minor.build
ProviderVersion Provider version generating the information, in the
form: major.minor.revision.build.
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames FailureDescription
VariableTypes 1 (String)