HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

Smart Array 306
Table 15-132 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name Property implementation
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
15.4.24Enclosure Temperature Sensor Status Changed to
Critical
Table 15-133 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at time of indication
PerceivedSeverity 5 (major)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Temperature sensor status has
changed to Critical. An enclosure temperature is
reaching the maximum allowed temperature for normal
operation. A shutdown is imminent. Action is required
before loss of data occurs.
AlertingMangedElement WBEM path of the HPSA_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 309
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP Smart Array
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.