HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

Smart Array 304
Table 15-131 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to OK
Property name Property implementation
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
15.4.23Enclosure Temperature Sensor Status Changed to
Warning
Table 15-132 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at time of indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Temperature sensor status
changed to Warning Condition. This indicates the
enclosure temperature is above normal, otherwise
enclosure is still operating normally.
AlertingMangedElement WBEM path of the HPSA_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 308
EventTime Time of the event or time of the indication if event time
unknown.
ProviderName HP Smart Array
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication