HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Smart Array 302
Table 15-130 HPSA_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded
Property name Property implementation
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
15.4.22Enclosure Temperature Sensor Status Changed to OK
Table 15-131 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at time of indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Temperature sensor status
changed from a non-OK state to OK.
AlertingMangedElement WBEM path of the HPSA_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 307
EventTime Time of the event or time of the indication if event time
unknown.
ProviderName HP Smart Array
RecommendedActions No action is recommended.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Temperature sensor status OK
EventCategory 24 (Primary Storage Cooling)
ProbableCause 1 (Other)