HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Smart Array 294
15.4.18Controller Cache Status – Permanently Disabled
Table 15-127 HPSA_DeviceIndication: Controller Cache status—Permanently Disabled
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at time of indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Smart Array controller Cache status has changed to
Permanently Disabled. The controller has detected a
problem with the cache and has disabled the cache
permanently.
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 11
EventTime Time of the event or time of the indication if event time
unknown.
ProviderName HP Smart Array
RecommendedActions Check the cache controller error code and run
diagnostics.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Array controller cache status permanently disabled
EventCategory 6 (Primary Storage)
ProbableCause 35 (Performance Degraded)
ProbableCauseDescription Array Controller Cache Status Changed to Permanently
Disabled
NetworkAddresses A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
• 70 (Windows Server 2003 64-bit)
OSType
• 77 (Windows Server 2008 64-bit)
• 103 (Windows Server 2008 R2)
OSVersion Operating system version of the computer system
generating the indication in the format,
major.minor.build
ProviderVersion Provider version generating the information, in the
form: major.minor.revision.build.