HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Smart Array 285
Table 15-122 HPSA_DeviceIndication: Controller Battery status changed to OK
Property name Property implementation
HWSerialNumber Array Controller Serial Number
HP_DeviceIndication
DeviceModel Array Controller Model string
15.4.14Controller Battery Status Changed to Not Fully
Charged
Table 15-123 HPSA_DeviceIndication: Controller Battery status changed to not fully charged
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at time of indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Smart Array controller Battery status has changed to
Not Fully Charged.
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 7
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP Smart Array
RecommendedActions Check battery operation, allow time to the battery to
be fully charged.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Controller Battery Status set to Not fully Charged.
EventCategory 6 (Primary Storage)
ProbableCause 99 (low battery)
ProbableCauseDescription Controller Battery Status Changed to Not Fully
Charged.