HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Smart Array 280
Table 15-120 HPSA_DeviceIndication: Controller Redundancy has been lost
Property name Property implementation
• VariableValues[0]: Short Description of failure
VariableValues
• VariableValues[1]:
HPSA_ArrayController.CacheSizeTotal
• VariableValues[2]:
HPSA_ArrayController.CacheSerialNumber
Note: In some cases the VariableValues property can
be N/A or "" (null).
• 3 (Enclosure) for c-Class blade systems
ImpactedDomain
• 4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the following
properties (indicated with *) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
HWFirmwareVersion Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer Array Controller Manufacturer string
HWSerialNumber Array Controller Serial Number
HP_DeviceIndication
DeviceModel Array Controller Model string
15.4.12Controller Redundancy Has Been Restored
Table 15-121 HPSA_DeviceIndication: Controller Redundancy has been restored
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at time of indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication