HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Smart Array 278
Table 15-119 HPSA_DeviceIndication: Controller Redundancy state has been set to ACTIVE
Property name Property implementation
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
HWFirmwareVersion Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer Array Controller Manufacturer string
HWSerialNumber Array Controller Serial Number
HP_DeviceIndication
DeviceModel Array Controller Model string
15.4.11Controller Redundancy Has Been Lost
Table 15-120 HPSA_DeviceIndication: Controller Redundancy has been lost
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at time of ndication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Smart Array controller has detected that redundancy
has been lost due to failure or loss of communication
with partner controller.
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 4
EventTime Time of the event or time of the indication if event time
unknown