HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Smart Array 274
Table 15-117 HPSA_DeviceIndication: Controller status changed to OK
Property name Property implementation
HWSerialNumber Array Controller Serial Number
HP_DeviceIndication
DeviceModel Array Controller Model string
15.4.9Controller Status Changed to ERROR
Table 15-118 HPSA_DeviceIndication: Controller status changed to ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A Smart Array controller status has changed to Error.
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 2
EventTime Time of the event or time of the indication if event time
unknown.
ProviderName HP SmartArray
RecommendedActions Check controller status and run diagnostics.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Controller status Error
EventCategory 6 (Primary Storage)
ProbableCause 24 (I/O device error)
ProbableCauseDescription Array Controller Status Changed to Error
NetworkAddresses A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
• 70 (Windows Server 2003 64-bit)
OSType
• 77 (Windows Server 2008 64-bit)
• 103 (Windows Server 2008 R2)