HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

Smart Array 272
15.4.8Controller Status Changed to OK
Table 15-117 HPSA_DeviceIndication: Controller status changed to OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 3 (Degraded/Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Smart Array controller status has changed from non-
OK to OK.
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1
EventTime Time of the event or time of the indication if event time
unknown.
ProviderName HP SmartArray
RecommendedActions No action is recommended.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Controller status OK
EventCategory 6 (Primary Storage)
ProbableCause 1 (Other)
ProbableCauseDescription Array Controller Status Changed to OK
NetworkAddresses A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
70 (Windows Server 2003 64-bit)
OSType
77 (Windows Server 2008 64-bit)
103 (Windows Server 2008 R2)
OSVersion Operating system version of the computer system
generating the indication in the format,
major.minor.build
ProviderVersion Provider version generating the information, in the
form: major.minor.revision.build.
SystemFirmwareVersion Firmware version of the computer system generating
the indication