HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Smart Array 269
Table 15-115 HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR
Property name Property implementation
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
HWLogicalLocation Logical drive number and RAID Level. (for example,
LogicalDrive 1 (RAID 1+0)).
HP_DeviceIndication
HPSA_StorageVolumeIndication
DeviceOperationalStatus Current OperationStatus values for Storage Volume
• DeviceOperationalStatus[0]:
HPSA_StorageVolume.OperationalStatus[0]
• DeviceOperationalStatus[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional
Vendor unique status available)
DeviceOperationalStatusPrevious Previous OperationStatus values for Storage Volume
• DeviceOperationalStatusPrevious[0]:
HPSA_StorageVolume.OperationalStatus[0]
• DeviceOperationalStatusPrevious[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional
Vendor unique status available)
15.4.7Logical Drive Status Changed to DEGRADED
Table 15-116 HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 3 (Degraded)
IndicationTime Time of indication
CIM_AlertIndication