HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Smart Array 267
Table 15-114 HPSA_StorageVolumeIndication: Logical Drive status changed to OK
Property name Property implementation
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
HP_HardwareIndication
HWLogicalLocation Logical drive number (for example, LogicalDrive 1
(RAID 1+0))
HP_DeviceIndication
HPSA_StorageVolumeIndication
DeviceOperationalStatus Current OperationalStatus values for Storage Volume
• DeviceOperationalStatus[0]:
HPSA_StorageVolume.OperationalStatus[0]
• DeviceOperationalStatus[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional
Vendor unique status available)
DeviceOperationalStatusPrevious Previous OperationalStatus values for Storage Volume
• DeviceOperationalStatusPrevious[0]:
HPSA_StorageVolume.OperationalStatus[0]
• DeviceOperationalStatusPrevious[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional
Vendor unique status available)
15.4.6Logical drive Status Changed to ERROR
Table 15-115 HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A logical drive status has changed to Error.
AlertingMangedElement WBEM path of the HPSA_StorageVolume class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 102
EventTime Time of the event or time of the indication if event time
unknown.
ProviderName HP SmartArray