Smart Array 265
Table 15-113 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE
Property name Property implementation
HWLogicalLocation Physical Disk Location string
For example, Port:1E Box: 1 Bay: 5
HWPhysicalLocation Physical Location of the Failed Drive (Bay Number)
DeviceControllerLogicalLocation Controller Location
For example, SmartArray 642 in Slot 2
HWManufacturer Compaq
HWSerialNumber Physical Disk Serial Number
HP_DeviceIndication
DeviceModel Physical Disk Model string
15.4.5Logical Drive Status Changed to OK
Table 15-114 HPSA_StorageVolumeIndication: Logical Drive status changed to OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication
Description A logical drive status has changed from a non-OK state
to OK.
AlertingMangedElement WBEM path of the HPSA_StorageVolume Class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 101
EventTime Time of the event or time of the indication if event time
unknown.
ProviderName HP SmartArray
RecommendedActions No action is recommended
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Logical drive status OK
EventCategory 6 (Primary Storage)