HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

Smart Array 263
Table 15-112 HPSA_DeviceIndication: Physical Drive status changed to REBUILDING
Property name Property implementation
HP_DeviceIndication
DeviceModel Physical Disk Model string
15.4.4Physical Drive Status Changed to PREDICTIVE FAILURE
Table 15-113 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A physical drive status has changed to Predictive
Failure.
AlertingMangedElement WBEM path of the HPSA_DiskDrive class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 204
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SmartArray
RecommendedActions Replace drive immediately to avoid loss of data.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical drive status Predictive Failure.
EventCategory 6 (Primary Storage)
ProbableCause 86 (Disk Failure)
ProbableCauseDescription Physical Drive Status Changed to Predictive Failure.
NetworkAddresses A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication.
70 (Windows Server 2003 64-bit)
OSType
77 (Windows Server 2008 64-bit)
103 (Windows Server 2008 R2)