HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Base server 26
Table 2-7 Class: HP_PowerManagementService Properties
Property name Property implementation
OperationalStatus 2 (OK)
StatusDescriptions StatusDescriptions[0] contains the following
corresponding to OperationalStatus[0]: Power
Management Service is OK
HealthState 5 (OK)
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledState 5 (Not Applicable)
RequestedState 12 (Not Applicable)
EnabledDefault 2 (Enabled)
CIM_Service
SystemName Computer system DNS name returned by Windows API
GetComputerSystemName()
Started True
SystemCreationClassName HP_WinComputerSystem
Name Server Power Management Service
CreationClassName HP_PowerManagementService
CIM_PowerManagmentService
HP_PowerManagmentService
Table 2-8 Implemented Methods for HP_PowerManagementService Class
Method name Method implementation
RequestPowerStateChange Method parameters:
• PowerState – Input parameter of the new power
state requested. Supported values are: Power On
(2), Power Cycle Soft Off (5), and Power Off Soft
(8).
• ManagedElement – Input parameter with the
reference to the HP_WinComputerSystem instance
for the power state change.
The Time, Job and TimeoutPeriod parameters are not
supported and should be zero or NULL.
For more information, see the DMTF Power State
Management Profile (DSP01027).
Note: Power Off and Power Cycle options are not
supported on HP Integrity systems.