HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Smart Array 259
Table 15-111 HPSA_DeviceIndication: Physical Drive status changed to ERROR
Property name Property implementation
A physical drive status has changed to
Error.
Description
AlertingMangedElement WBEM path of the HPSA_DiskDrive class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 202
EventTime Time of the event or time of the indication if event time
unknown.
ProviderName HP SmartArray
RecommendedActions Check for failed or removed physical drives.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical drive status Error.
EventCategory 6 (Primary Storage)
ProbableCause 86 (Disk Failure)
ProbableCauseDescription Physical Drive Status Changed to Error
NetworkAddresses A list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
• 70 (Windows Server 2003 64-bit)
OSType
• 77 (Windows Server 2008 64-bit)
• 103 (Windows Server 2008 R2)
OSVersion Operating system version of the computer system
generating the indication in the format,
major.minor.build
ProviderVersion Provider version generating the information, in the
form: major.minor.revision.build.
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication