HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Smart Array 232
Table 15-32 Class: HPSA_StorageCapabilities (CIM_StorageCapabilities)
Property name Property implementation
• 1—When number of drives is an odd number
DataRedundancyDefault
• 2—When number of drives is an even number
(For example, pool can be configured for
mirroring.)
• 0—When there is no drives connected
• 1—When number of drives is an odd number
DataRedundancyMax
• 2—When number of drives is an even number
(For example, Pool can be configured for
mirroring.)
• 0—When there is no drives connected
DataRedundancyMin 1
DeltaReservationDefault 0
DeltaReservationMax 0
DeltaReservationMin 0
ElementType 5 (Storage Pool)
• True—When number of drives > 1 (For example,
pool can be configured for redundancy.)
NoSinglePointOfFailure
• False—When number of drives <= 1
• True—When number of drives > 1 (For example,
pool can be configured for redundancy.)
NoSinglePointOfFailureDefault
• False—When number of drives <= 1
• 0 (When number of drives <= 1)
PackageRedundancyDefault
• 1 (When number of drives = 2 or 3)
• 2 (When number of drives > 3)
• 0 (When number of drives <= 1)
PackageRedundancyMax
• 1 (When number of drives = 2 or 3)
• 2 (When number of drives > 3)
PackageRedundancyMin 0
HPSA_StorageCapabilities
15.3.32HPSA_Product
HPSA_Product represents the top level marketing information for the Array System.
Table 15-33 Class: HPSA_Product (CIM_Product)
Property name Property implementation
CIM_ManagedElement