HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Smart Array 231
Table 15-31 Class: HPSA_ArrayControllerLocation (HP_Location)
Property name Property implementation
ElementLocationTag for Internal HBAs: PCI Slot Number
Examples:
• 3 – for adapter in PCI Slot 3
• 0 – for Embedded adapter
For external controllers: Controller number per chassis
label
Examples:
• Controller 1
• Controller 2
• 23 (Adapter)—for Internal HBAs
ElementLocationTagDesc
• 1 (Hood Tag)—for External Controllers
LocationInformation[0] For internal HBAs: PCI Slot number
Examples:
• 3 – PCI Slot 3
• 0 – Embedded on Motherboard
Not required for External Storage Systems
• 3 (PCI Slot) – for internal HBAs
LocationInfoDesc[0]
• Not required for External Storage Systems
HP_ArrayControllerLocation
15.3.31HPSA_StorageCapabilities
HPSA_StorageCapabilities represents the possible capabilities of a Storage Pool.
Table 15-32 Class: HPSA_StorageCapabilities (CIM_StorageCapabilities)
Property name Property implementation
CIM_ManagedElement
ElementName For Primodial Pools: Controller name and location
Examples:
• Smart Array in Slot 3, for internal
• Active Controller: MSA500 in SystemCab03, for
external
For Concrete Pools: Controller name and
location:Array identifier
Examples:
• Smart Array in Slot 3: Array – 0, for internal
• Active Controller: MSA500 in SystemCab03:
Array – 1, for external
CIM_Capabilities
InstanceID Key: Opaque key
CIM_StorageCapabilities