HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Smart Array 223
Table 15-21 Class: HPSA_StorageSetting (CIM_StorageSetting)
Property name Property implementation
PackageRedundancyGoal Desired number of redundant packages to be used.
• 0 (RAID 0)
• 1 (RAID 1+0, RAID 5)
• 2 (RAID 6)
PackageRedundancyMax Maximum number of redundant packages to be used.
• 0 (RAID 0)
• 1 (RAID 1+0, RAID 5)
• 2 (RAID 6, RAID 50, RAID 60)
PackageRedundancyMin Minimum number of redundant packages to be used.
• 0 (RAID 0)
• 1 (RAID 1+0, RAID 5)
• 2 (RAID 6, RAID 50, RAID 60)
HPSA_StorageSetting
15.3.21HPSA_DriveCage
HPSA_DriveCage represents the drive cage assembly and back plane within a storage enclosure.
There can be multiple instances within a duplexed enclosure.
Table 15-22
Class: HPSA_DriveCage (CIM_PhysicalPackage)
Property name Property implementation
CIM_ManagedElement
ElementName
Port m Box n,where m is the name of the port to which
this drive cage is connected and n is the name of the
box number.
For example, Port J3 Box 1
CIM_ManagedSystemElement
Name Serial Number of the drive cage
When the serial number is not available, this field is
empty.
OperationalStatus Operational Status of the DriveCage
CIM_PhysicalElement
CreationClassName HPSA_DriveCage
Manufacturer Drive Cage Vendor string
Model Drive Cage Model string
PartNumber Not populated – Not available in this implementation
Tag Opaque key
SerialNumber Enclosure Serial number
Version Nor populated — Not available in this implementation