HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Smart Array 222
Table 15-20 Class: HPSA_MediaAccessStatData (CIM_MediaAccessStatData)
Property name Property implementation
RetryRecoveredReadErrors See HP Smart Array Profile
RetryRecoveredWriteErrors See HP Smart Array Profile
15.3.20HPSA_StorageSetting
HPSA_StorageSetting represents the current raid configuration for a Storage Volume. There is one
instance per Storage Volume.
Table 15-21 Class: HPSA_StorageSetting (CIM_StorageSetting)
Property name Property implementation
CIM_ManagedElement
ElementName
RAID n, where n is the raid description.
Examples:
• RAID 0
• RAID 1+0
• RAID 5
• RAID 6
CIM_SettingData
InstanceID Opaque key
CIM_StorageSetting
ChangeableType 0 (Not Changeable)
DataRedundancyGoal Desired number of complete copies of data to be
maintained.
• 1 (RAID 0, RAID 5, RAID 6, RAID 50, RAID 60)
• 2 (RAID 1+0)
DataRedundancyMax Maximum number of complete copies of data to be
maintained.
• 1 (RAID 0, RAID 5, RAID 6, RAID 50, RAID 60)
• 2 (RAID 1+0)
DataRedundancyMin Minimum number of complete copies of data to be
maintained.
• 1 (RAID 0, RAID 5, RAID 6, RAID 50, RAID 60)
• 2 (RAID 1+0)
DeltaReservationGoal 0
DeltaReservationMax 0
DeltaReservationMin 0
• FALSE – RAID 0
NoSinglePointOfFailure
• TRUE – RAID 1+0, RAID 5, RAID 6, RAID 50,
RAID 60