HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

Base server 22
Table 2-3 Dedicated and OtherDedicatedDescription Values by System
System HP_ComputerSystem.Dedicated[ ] HP_ComputerSystem.OtherDedicatedDes
cription[0]
Modular
Single blade. For
example:
Dedicated[0]: 2 (Other)
Integrity BL860c
Integrity BL870c
Integrity BL860c i2
Modular
Conjoined blades. For
example:
Dedicated[0]: 2 (Other)
Integrity BL870c i2
Integrity BL890c i2
Cellular
Dedicated[0]: 2 (Other)
Cellular partition (single-
cell or multi-cell). For
example:
Dedicated[1]: 32569 (Physical
Partition)
Superdome 16B
Dedicated[2]: 32571 (Cell
Board)
Superdome 32B
Superdome 64B
Dedicated[0]: 0 (Not Dedicated) Empty
Single-node (non-
cellular servers). For
examples
Integrity rx3600
Integrity rx6600
2.3.2 HP_ComputerSystemChassis
HP_ComputerSystemChassis extends the class CIM_ComputerSystemChassis to model the physical
system chassis. Only one instance of HP_ComputerSystemChassis is instantiated on an Integrity
server.
The following properties are implemented.
Table 2-4 Class: HP_ComputerSystemChassis
Property name Property implementation
CIM_ManagedSystemElement