HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

Smart Array 217
Table 15-14 Class: HPSA_DAPort (CIM_DAPort)
Property name Property implementation
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault 2 (Enabled)
EnabledState 5 (Not Applicable)
RequestedState 12 (Not Applicable)
CIM_LogicalDevice
CreationClassName HPSA_DAPort
DeviceID Opaque key
SystemCreationClassName HPSA_ArraySystem
SystemName HPSA_ArraySystem.Name
CIM_LogicalPort
UsageRestriction 2 (Front-End Only)
82(PCI)
PortType
83(PCI-x)
The provider always displays 82 (PCI), not 83(PCI-x).
Currently, the provider cannot display the 83 value for
PCI-X controllers.
CIM_DAPort
HPSA_DAPort
15.3.14HPSA_SPIPort
HPSA_SPIPort represents the front-end port for an external Storage Subsystem. SPI implies that the
subsystem is connected through SCSI Parallel Interface to the Host.
Table 15-15 Class: HPSA_SPIPort (CIM_SPIPort)
Property name Property implementation
CIM_ManagedElement
ElementName Storage System name and location (for example,
MSA500 in SystemCab03)
CIM_ManagedSystemElement
OperationalStatus[0] Port status
0 (Unknown)
2 (OK)
6 (Error)
CIM_LogicalElement