HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

Smart Array 203
Table 15-2 Class: HPSA_ArraySystem (CIM_ComputerSystem)
Property name Property implementation
CIM_ManagedElement
ElementName Controller/Storage System name and location
Examples:
Smart Array in Slot 3, for internal
MSA500 in SystemCab03, for external
CIM_ManagedSystemElement
Controller Serial Number
Name
EMBEDDED – Reported if there is no Serial
Number for the local device (embedded on the
motherboard).
OperationalStatus[0] Overall status of the Array System and attached
devices. This is calculated per the algorithm desciribed
in the HP Smart Array Profile.
0 (Unknown)
2 (OK)
3 (Degraded)
6 (Error)
StatusDescriptions[0] More information for OperationalStatus result. This
provides a short decription to identify who is
contributing to non-OK status.
Examples:
Logical Drive Failure
Physical Drive Degraded/Failed
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault 2 (Enabled)
EnabledState 5 (Not Applicable)
RequestedState 12 (Not Applicable)
CIM_System
CreationClassName HPSA_ArraySystem
NameFormat Other
CIM_ComputerSystem
Dedicated[0]: 3 (Storage) or 30 (Host-based RAID
controller)
Dedicated
Dedicated[1]: 15 (Block Server)
IdentifyingDescriptions Other Vendor Specific Name
OtherIdentifyingInfo Controller Serial Number
Identify() See HP Smart Array Profile