HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

Ethernet Teaming 173
Table 13-26 HP_AlertIndication: Ethernet Team Redundancy Increased
Property name Property implementation
3 (Enclosure) for c-Class blade systems
ImpactedDomain
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the following
properties (indicated with *) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment.
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment.
13.4.3Ethernet Team Redundancy Decreased
Table 13-27
HP_AlertIndication: Ethernet Team Redundancy Decreased
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Degraded/Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description An Ethernet team's redundancy has decreased. A team
member has changed to failed or degraded state.
AlertingManagedElement WBEM path of the Ethernet Team
(HP_WinEthRedundancySet) reporting decreased
redundancy
AlertingElementFormat 2 (CIMObjectPath)
AlertType 2 (Communications Alert)
Event Id 4
ProbableCause 88 (Loss of Redundancy)
ProbableCause Description Ethernet Team Redundancy Decreased
Provider Name HP Ethernet