HP Insight Management WBEM Providers for Windows on Integrity Data Sheet
Blade System Lite 152
Table 12-10 Class: HP_Location
Property name Property implementation
Name Unique identifier for this blade bay location instance.
For example: HPQ:HP_BladeCSLocation:Bay number
PhysicalPosition n, where n represents the blade bay slot position
printed on the enclosure labeling.
HP_Location
ElementLocationTag The computer system name
ElementLocationTagDesc 24 (Blade)
LocationInformation LocationInformation[0]:
The blade bay number within the enclosure
LocationInfoDesc LocationInfoDesc[0]:
14 (Blade Bay)
12.3.10HP_ElementLocation
HP_ElementLocation is used to represent an association between CIM_Location and
CIM_ManagedElement. The Windows specific implementation class is HP_BladeCSElementLocation.
Table 12-11
Class: CIM_InstalledSoftwareIdentity
Property name Property implementation
Element References CIM_ManagedElement
PhysicalLocation References CIM_Location
12.4Supported indications
There are no indications specific to the blade system profile implementation.