HP Insight Management WBEM Providers for Windows on Integrity Data Sheet

System memory 104
Table 7-19 Class: HP_ MemoryBoardSlotLocation
Properties Property implementation
Caption A string describing the memory board physical
location:
System Board
Extender x
Cabinet x Cell y
Description A string describing the memory board physical
location:
System Board
Extender x
Cabinet x Cell y
ElementName A string describing the memory board physical
location:
System Board
Extender x
Cabinet x Cell y
CIM_Location
Name A string describing the memory board physical
location:
System Board
Extender x
Cabinet x Cell y
PhysicalPosition One of the following:
x (on non-cellular and Blade systems), where x is
the board number.
c-x (on cellular systems), where c is the cabinet
number and x is the cell number.
HP_Location
ElementLocationTag One of the following:
x (on non-cellular and Blade systems), where x is
the board number.
c-x (on cellular systems), where c is the cabinet
number and x is the cell number.
4 (Cell)
ElementLocationTagDesc
9 (Memory Board)
24 (Blade)
LocationInformation
LocationInformation[0] text: x, where x is the
board/cartridge number
LocationInfoDesc[0] = 5 (Memory Board)
LocationInfoDesc
LocationInfoDesc[0] = 10 (Cell)
LocationInfoDesc[0] = 14 (Blade Bay)
Either indicates the first element of the
LocationInformation array contains the board or
cartridge number.