Array Configuration Utility User Guide

Scripting in ACU 40
ACU scripting error messages
Message Comment or explanation (if not self-explanatory)
(text) is not a controller command --
(text) is not a logical drive
command
--
(text) is not a supported command --
(text) is not an array command --
(text) command expected
The specified command is missing or in the incorrect place in the
file.
Array not specified
Some commands in the script require an array, but no array is
specified in the script file.
Array requires an odd number of
drives
This error message occurs if you attempt to add an odd number of
drives to an existing array that has RAID 1 logical drives, and the
controller does not support RAID-level migration.
Cannot change array spare
The current configuration does not allow the number of spares in the
array to be changed.
Cannot change logical drive array
accelerator setting
The current controller configuration does not allow the array
accelerator setting to be changed.
Cannot change logical drive
sectors
You cannot change the MaxBoot setting on a configured logical
drive because doing so causes data loss.
Cannot change SSP settings --
Cannot create array
The controller either has no unassigned physical drives, or it already
has the maximum number of arrays or logical drives.
Cannot create logical drive
There is no free space on the array, or the maximum number of
logical drives has already been reached.
Cannot expand array
The controller does not support expansion, or the current
configuration of the controller does not allow expansion.
Cannot extend logical drive
The controller does not support extension, or the current
configuration does not allow extension. For example, if there is no
free space on an array, extension is not supported.
Cannot migrate logical drive RAID
The controller does not support RAID migration, or the current
configuration of the controller does not allow migration.
Cannot migrate logical drive stripe
size
The controller does not support stripe size migration, or the current
configuration of the controller does not allow migration.
Cannot remove physical drives
from existing array
You have inadvertently omitted one or more physical drives from the
drive list when reconfiguring an existing array. ACU does not allow
this because removing physical drives from a configured array
causes data loss.
Controller (text) is invalid The controller specifications are not entered correctly.
Controller does not support
controller SSPState. Use the
LogicalDriveSSPState command to
set SSP states for each logical
drive.
--
Controller does not support license
keys
--