A7298A HBA Installation Guide
Troubleshooting
53Host Bus Adapter for Windows and Linux Installation Guide
0xE2 Mailbox cmd time-out 0x11 = command
0xE3 Mailbox rsp err 0x11 = command, 12-13 =
mbxstatus
0xE4 HBA not ready after init Status register bytes 1-3 in event
11-13
0xE5 Requested loop but link = PT-PT
0xE6 Mailbox int. but cmd not
complete
0x11 = MB cmd, 12-13 = mbxstatus
0xE7 SRB already queued to ring
0xE8 RESTART failed
0xE9 PORT BYPASS (LPB) received
0xEB Unknown IOCB cmd rsp 0x11 = 15:8 = cmd field
0xEC Uncached extension alloc. Error
0xED Link down @ boot time (30 sec)
0xEF Too many interrupts at initial
boot
0xF0 Rcv ELS request (possible logout)
(Windows NT)
0x11 = ELS type, 12-13 = X_ID
0xF1 LinkUp error; LP8 down, driver
up
0x11 = parameter field, 12 = IOCB
cmd
0xF2 LinkUp w/ illegal or corrupt RPI 0x11 = parameter field, 12 = IOCB
cmd
0xF3 DeQueue ring->iotcmd.head 0x11 = caller ID
0xF4 HBA reset 0x11 = coded reason for reset:
Bit 0 = IOCB requeue; bit 1 = readla
retry
Bit 2 = initlink retry; bit 3 = rstbus
retry
Bit 4 = mailbox time-out
0xF5 PCP_IXXX_CR IOCB rsp err 0x11 = cmdstat, 12 = parm err, 13 =
ALPA
Table 5: SCSI Port Error Log Codes (Continued)
0x10
Offset
Explanation
0x11 to 0x13 Further
Information