Table 1-3 Computer pin-outs or HP Integrity rx5670 servers
DB9 Female PinWire ColorRJ45 Pin
1Blue1
3Orange2
2Black3
4Red4
5Green5
6Yellow6
7Brown7
8Gray (White)8
Table 1-4 Computer pin-outs for HP Integrity rx7620 and rx8620 servers
DB9 Female PinWire ColorRJ45 Pin
4Blue1
8Orange2
5Black3
3Red4
2Green5
NCYellow6
7Brown7
6Gray (White)8
Table 1-5 Computer pin-outs for HP Integrity Superdome/sx1000 servers
DB9 Female PinWire ColorRJ45 Pin
7Blue1
5Orange2
NCBlack3
8Red4
3Green5
NCYellow6
2Brown7
NCGray (White)8
Setting up and connecting to the target machine
To set up the server and initiate local debugging, complete the following steps:
1. Change the boot configuration (required for all servers).
2. Locate and enable the correct debug port (required for cell-based servers with multiple
operating system instances and BL860c/BL870c blade servers).
3. Connect the host machine to the server debugging port.
Setting up and connecting to the target machine 13