Windows® event ID Base hardware event description Target class
8716 IO subsystem has a critical failure Logs (Integrity SNMP)
8717 IO subsystem has failed Logs (Integrity SNMP)
8718 IO subsystem has failed Logs (Integrity SNMP)
8719 IO subsystem has a critical failure Logs (Integrity SNMP)
8720 IO subsystem has a critical failure Logs (Integrity SNMP)
8721 IO subsystem has failed Logs (Integrity SNMP)
8722 IO subsystem has a critical failure Logs (Integrity SNMP)
8723 IO subsystem has a critical failure Logs (Integrity SNMP)
8756 Non-volatile storage has data error Logs (Integrity SNMP)
8758 SAL has failed Logs (Integrity SNMP)
8768 Memory configuration has resulted in a
warning
Logs (Integrity SNMP)
8784 System hardware has failed Logs (Integrity SNMP)
8787 System hardware has failed Logs (Integrity SNMP)
8797 An error in complex profile data has occurred Logs (Integrity SNMP)
8798 PAL has failed Logs (Integrity SNMP)
8806 Log is full or access to log has failed Logs (Integrity SNMP)
8807 Log is full or access to log has failed Logs (Integrity SNMP)
8814 Cell configuration has resulted in a warning Logs (Integrity SNMP)
8817 Power supply has a critical failure Logs (Integrity SNMP)
8818 Temperature sensor has failed Logs (Integrity SNMP)
8819 System firmware has issued an error Logs (Integrity SNMP)
8821 Memory configuration has resulted in a
warning
Logs (Integrity SNMP)
8828 System firmware has issued an error Logs (Integrity SNMP)
8837 System configuration has resulted in a warning Logs (Integrity SNMP)
8839 Cell board has a critical failure Logs (Integrity SNMP)
8855 System firmware has issued an error Logs (Integrity SNMP)
8857 Processor has failed Logs (Integrity SNMP)
8858 Processor has failed Logs (Integrity SNMP)
8859 System firmware has issued a warning Logs (Integrity SNMP)
8860 System firmware has issued a warning Logs (Integrity SNMP)
8861 System firmware has issued a warning Logs (Integrity SNMP)
8864 System firmware has issued a warning Logs (Integrity SNMP)
8865 System firmware has issued a warning Logs (Integrity SNMP)
8872 Cell configuration has resulted in an error Logs (Integrity SNMP)
8877 Processor has failed Logs (Integrity SNMP)
8882 Processor configuration has resulted in a
warning
Logs (Integrity SNMP)
8883 Non-volatile storage has invalid data Logs (Integrity SNMP)
8906 Management controller has failed Logs (Integrity SNMP)
8940 Cell board has a critical failure Logs (Integrity SNMP)
8941 Cell board has a critical failure Logs (Integrity SNMP)
8942 Cell board has a critical failure Logs (Integrity SNMP)
Event rules for HP Integrity servers 126