Microsoft Operations Manager Integration Pack Guide (2007), v5.5

Windows® Event ID Storage server event description Target class
1065 Drive array accelerator degraded or
failed or battery failed
Storage (ProLiant SNMP)
1066 Drive array accelerator degraded or
data degraded or failed
Storage (ProLiant SNMP)
1067 Drive array accelerator degraded or
failed or battery failed
Storage (ProLiant SNMP)
1075 Storage system fan degraded Storage (ProLiant SNMP)
1076 Storage system temperature failed Storage (ProLiant SNMP)
1077 Storage system temperature degraded Storage (ProLiant SNMP)
1101 Storage system side panel degraded Storage (ProLiant SNMP)
1104 Storage system fault-tolerant power
supply degraded
Storage (ProLiant SNMP)
1107 SCSI tape drive failed Storage (ProLiant SNMP)
1119 SCSI tape drive degraded Storage (ProLiant SNMP)
1120 SCSI tape drive degraded Storage (ProLiant SNMP)
1121 IDE drive degraded Storage (ProLiant SNMP)
1145 External array logical drive failed Storage (ProLiant SNMP)
1146 External array physical drive failed Storage (ProLiant SNMP)
1147 External array spare drive failed Storage (ProLiant SNMP)
1148 External array accelerator failed or data
failed or battery failed
Storage (ProLiant SNMP)
1149 External array accelerator failed or data
failed or battery failed
Storage (ProLiant SNMP)
1150 External array accelerator failed or data
failed or battery failed
Storage (ProLiant SNMP)
1151 External array controller degraded or
failed
Storage (ProLiant SNMP)
1152 Storage system fan degraded Storage (ProLiant SNMP)
1153 Storage system power supply degraded Storage (ProLiant SNMP)
1154 Storage system power supply UPS
degraded
Storage (ProLiant SNMP)
1155 Storage system temperature degraded Storage (ProLiant SNMP)
1156 SCSI tape library failed Storage (ProLiant SNMP)
1158 SCSI tape library degraded Storage (ProLiant SNMP)
1159 SCSI tape library door degraded
(disabled at default)
Storage (ProLiant SNMP)
1161 SCSI CD library degraded Storage (ProLiant SNMP)
1164 Drive array controller degraded Storage (ProLiant SNMP)
1165 Drive array controller degraded Storage (ProLiant SNMP)
1173 Fibre Channel tape controller degraded Storage (ProLiant SNMP)
1174 Fibre Channel tape library degraded Storage (ProLiant SNMP)
1175 Fibre Channel tape library door
degraded
Storage (ProLiant SNMP)
1176 Fibre Channel tape drive degraded Storage (ProLiant SNMP)
1177 Fibre Channel tape drive degraded Storage (ProLiant SNMP)
1178 Fibre Channel tape drive degraded Storage (ProLiant SNMP)
Event rules for HP ProLiant servers 111