Management Agents Events Reference

Event DescriptionEvent SeverityEvent ID
An error was encountered while routing the fabric. This error prevents an appropriate
route from being selected. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32
| return status. Probable Cause: An error occurred while routing the fabric.
Recommended Action: Contact your HP support representative to inspect the fabric
and system firmware. SNMP Trap: hpevtErrEncntRoutFabPrvntRoutSel - 11040 in
HPIFPTRAP.MIB.
Warning11040
An invalid port number was returned when selecting a route for the XBC-CC link.
Data Field: (destination cell 56) | (xbc port 44) | (xbc # 32) | port selected. Probable
Cause: An error occurred while routing the fabric. Recommended Action: Contact
your HP support representative to inspect the fabric and system firmware. SNMP
Trap: hpevtInvlPrtRetRoutXbcCcLnk - 11041 in HPIFPTRAP.MIB.
Warning11041
An error was encountered while routing the fabric. This error prevents an appropriate
route from being selected. Data Field: Destination Cell 56 | XBC Port 44 | XBC # 32
| switch fabric. Probable Cause: An error occurred while routing the fabric.
Recommended Action: Contact your HP support representative to inspect the fabric
and system firmware. SNMP Trap: hpevtErrEncntRoutFabPrvntRoutSelSw - 11042
in HPIFPTRAP.MIB.
Warning11042
The second flash part is not programmed with a valid image. SNMP Trap:
hpevtSecndFlshNotProgrmValidImg - 11052 in HPIFPTRAP.MIB.
Warning11052
System backplane power has reported a 1.2v LDO fault. The data field contains the
physical location of the fault. Probable Cause: System backplane power board has
reported a 1.2v LDO fault. Recommended Action: Check system backplane. SNMP
Trap: hpevtSysBckPlnPwr1p2LDOFault - 11452 in HPIFPTRAP.MIB.
Error11452
System backplane power has reported a 2.5v LDO fault. The data field contains the
physical location of the fault. Probable Cause: System backplane power board has
reported a 2.5v LDO fault. Recommended Action: Check system backplane. SNMP
Trap: hpevtSysBckPlnPwr2p5LDOFault - 11454 in HPIFPTRAP.MIB.
Error11454
System backplane power has reported a 3.3v house keeping power fault. The data
field contains the physical location of the fault. Probable Cause: System backplane
power board has reported a 3.3v house keeping fault. Recommended Action: Check
system backplane power board. SNMP Trap: hpevtSysBckPlnPwr3p3HseFault -
11456 in HPIFPTRAP.MIB.
Error11456
System backplane power has reported a 12v power fault. The data field contains the
physical location of the fault. Probable Cause: System backplane power board has
reported a 12v fault. Recommended Action: Check system backplane power board.
SNMP Trap: hpevtSysBckPlnPwr12Fault - 11459 in HPIFPTRAP.MIB.
Error11459
System backplane power has reported a 3.3v power fault. The data field contains the
physical location of the fault. Probable Cause: System backplane power board has
reported a 3.3v fault. Recommended Action: Check system backplane power board.
SNMP Trap: hpevtSysBckPlnPwr3p3Fault - 11461 in HPIFPTRAP.MIB.
Error11461
System backplane power has reported a 1.5v power fault. The data field contains the
physical location of the fault. Probable Cause: System backplane power board has
reported a 1.5v fault. Recommended Action: Check system backplane power board.
SNMP Trap: hpevtSysBckPlnPwr1p5Fault - 11463 in HPIFPTRAP.MIB.
Error11463
System backplane power has reported a 2.5v power fault. The data field contains the
physical location of the fault. Probable Cause: System backplane power board has
reported a 2.5v fault. Recommended Action: Check system backplane power board.
SNMP Trap: hpevtSysBckPlnPwr2p5Fault - 11465 in HPIFPTRAP.MIB.
Error11465
One or more power rails is providing insufficient power to the backplane. Probable
Cause: There has been multiple faults on the same power rail. Recommended Action:
look for additional events describing action to take. SNMP Trap:
hpevtPwrRailPrvInsuffPwrToBckPln - 11467 in HPIFPTRAP.MIB.
Error11467