Management Agents Events Reference
Event DescriptionEvent SeverityEvent ID
The left cell latch is open. SNMP Trap: hpevtCellLatchOpen - 10060 in
HPIFPTRAP.MIB.
Warning10060
Right ejector latch is open. Probable Cause: The right ejector latch is open.
Recommended Action: Close the right ejector latch on the specified cell. SNMP Trap:
hpevtDcnfgRightCellLatch - 10061 in HPIFPTRAP.MIB.
Warning10061
The optical emitters on the cell latch sensors are not functioning. Probable Cause:
There is a hardware failure. Recommended Action: The cell board must be repaired
or replaced. SNMP Trap: hpevtCellLatchSensorBad - 10062 in HPIFPTRAP.MIB.
Warning10062
The vrm on the specified cell is reporting a voltage fault. Probable Cause: The specified
vrm is reporting a fault. Recommended Action: Replace the specified VRM. The
datafield contains the physical location. Byte 16 is the cabinet, byte 13 is the cell slot,
and byte 11 is the vrm slot. The vrm slot in byte 11 matches the vrm number
silkscreened on the cell board. SNMP Trap: hpevtVrmVltFault - 10063 in
HPIFPTRAP.MIB.
Warning10063
The vrm on the specified cell is reporting a temperature fault. SNMP Trap:
hpevtVrmTempFlt - 10064 in HPIFPTRAP.MIB.
Warning10064
The rail on a cell is reporting a fault. SNMP Trap: hpevtVrmFlt - 10065 in
HPIFPTRAP.MIB.
Warning10065
A I/O backplane vrm is reporting a voltage fault. SNMP Trap: hpevtVrmIoVltFlt -
10068 in HPIFPTRAP.MIB.
Warning10068
A I/O backplane power brick is reporting a voltage fault. SNMP Trap:
hpevtPwrBrickVltFlt - 10069 in HPIFPTRAP.MIB.
Warning10069
A I/O backplane vrm is reporting a temperature fault. SNMP Trap:
hpevtVrmBkPlaneTempFlt - 10070 in HPIFPTRAP.MIB.
Warning10070
A I/O backplane power brick is reporting a temperature fault. SNMP Trap:
hpevtBkPlanePwrBrickTempFlt - 10071 in HPIFPTRAP.MIB.
Warning10071
A I/O backplane vrm rail is reporting a fault. SNMP Trap: hpevtBkPlanVrmRailFlt
- 10072 in HPIFPTRAP.MIB.
Warning10072
A I/O backplane power brick is reporting a rail fault. SNMP Trap:
hpevtBkPlanePwrBrkFlt - 10073 in HPIFPTRAP.MIB.
Warning10073
The specified system backplane vrm is reporting a module voltage fault. SNMP Trap:
hpevtBkPlaneVrmVltFlt - 10103 in HPIFPTRAP.MIB.
Warning10103
The specified system backplane vrm is reporting a temperature fault. SNMP Trap:
hpevtBkPlaneVrmTempFlt - 10104 in HPIFPTRAP.MIB.
Warning10104
The specified system backplane rail is reporting a fault SNMP Trap: hpevtBkPlaneFlt
- 10105 in HPIFPTRAP.MIB.
Warning10105
Master MP failure. Slave MP has taken control SNMP Trap: hpevtMstrMpFailed -
10115 in HPIFPTRAP.MIB.
Warning10115
The NVRAM service was unable to satisfy an NVRAM allocation request. Probable
Cause: NVRAM is full. This is extremely unlikely. Recommended Action: Clear
NVRAM and reset. SNMP Trap: hpevtNvramAlloc - 10116 in HPIFPTRAP.MIB.
Error10116
The RTC not updating its internal time registers. Probable Cause: Bad RTC chip on
the PDH daughtercard. Recommended Action: Replace PDH daughtercard SNMP
Trap: hpevtRtcTimeReg - 10132 in HPIFPTRAP.MIB.
Error10132
Uncorrectable PAA fault on MX2. Probable Cause: An uncorrectable PAA fault has
occurred on the MX2 module and PAA firmware has halted. Recommended Action:
Contact your HP support personnel. SNMP Trap: hpevtPAAFltMx2 - 10159 in
HPIFPTRAP.MIB.
Warning10159
72 Management Agents Event Tables