Management Agents Events Reference

Event DescriptionEvent SeverityEvent ID
Cell about to be halted because CPU couldn't change its CPU FP (PST) state. Probable
Cause: Hardware problem with the cell (like PDH memory) or the CC or CPU.
Recommended Action: Contact HP support to troubleshoot or replace the cell board.
SNMP Trap: hpevtBootMoveSlavesFpSetErr - 9371 in HPIFPTRAP.MIB.
Warning9371
Partition about to be reset because PDC couldn't get address to a structure. Probable
Cause: Hardware connecting cells in the partition experienced a problem such that
cells in the partition together can no longer communicate. Recommended Action:
Troubleshoot the fabric and replace backplane or cells. Gather event logs and contact
HP Customer Support for assistance. SNMP Trap:
hpevtBootMoveCellMonarchsStructAddrErr - 9372 in HPIFPTRAP.MIB.
Error9372
Resetting a partition because a CPU didn't complete the task it was awakened for.
Probable Cause: Hardware problem with the CPU chip, CC chip, or PDH flash.
Recommended Action: Troubleshoot the cell and/or replace it. Contact HP Customer
Support for assistance. SNMP Trap: hpevtBootMoveCellMonarchsCheckSlaveErr -
9373 in HPIFPTRAP.MIB.
Error9373
Resetting partition because PDC couldn't determine relocated address of code.
Probable Cause: Cell was unable to access its own PDH memory. Recommended
Action: Troubleshoot the cell board and replace it if necessary. Contact HP Customer
Support for assistance. SNMP Trap: hpevtBootMoveCellMonarchsFpSetAddrErr -
9375 in HPIFPTRAP.MIB.
Error9375
Resetting partition because a CPU was unable to change its CPU FP state. Probable
Cause: Hardware problem with PDH memory, CC chip, or the CPU chip.
Recommended Action: Troubleshoot the cell and/or replace it. Contact HP Customer
Support for assistance. SNMP Trap: hpevtBootMoveCellMonarchsFpSetErr - 9376 in
HPIFPTRAP.MIB.
Error9376
CPU Dual Core Initialization Failed. Probable Cause: MX2 initialization failed.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. SNMP Trap: hpevtBootDualCoreInitFail - 9379 in HPIFPTRAP.MIB.
Warning9379
Second CPU in Pair has been disabled. Probable Cause: The second CPU in the Dual
Core has been deconfigured as a result of the first core being deconfigured.
Recommended Action: Investigate the cause of the first core being deconfigured
SNMP Trap: hpevtBootDeconfigCpuModulePair - 9380 in HPIFPTRAP.MIB.
Warning9380
Virtualzing Dual Core Registers Failed. Probable Cause: FW failed to virtualize the
mx2 interposer. Recommended Action: Reboot. If problem persists contact your HP
representative for support. SNMP Trap: hpevtBootVirtualizeDualCoreRegistersFail
- 9382 in HPIFPTRAP.MIB.
Error9382
Virtualizing Dual Core Interposer has failed. Probable Cause: Virtualizing the Dual
Core Interposer has failed. Recommended Action: Reboot. If problem persists contact
your HP representative for support. SNMP Trap:
hpevtBootVirtualizeDualCoreInterposerFail - 9383 in HPIFPTRAP.MIB.
Warning9383
Install PMI Handler Failed. Probable Cause: Installation of the FW PMI handler has
failed. Recommended Action: Reboot. If problem persists contact your HP
representative for support. SNMP Trap: hpevtBootInstallPmiHandlerFailed - 9385
in HPIFPTRAP.MIB.
Error9385
Cell failed compatibility checks. Probable Cause: A Cell or CPU module's FRU data
is programmed incorrectly. Recommended Action: If this is in manufacturing,
re-program the FRU specific field of the FRU data for the cell or CPU module.
Otherwise, contact HP Support personnel to troubleshoot the problem. SNMP Trap:
hpevtPdhcCellIncompatable - 9388 in HPIFPTRAP.MIB.
Error9388
PDH space not available after release from reset. Probable Cause: A hardware fault
has occurred. Recommended Action: Contact HP Support personnel to troubleshoot
the Cell Board, Cell Power Board and PDH Daughtercard. SNMP Trap:
hpevtPdhcPdhNotAvailable - 9389 in HPIFPTRAP.MIB.
Error9389
Platform Agent Events 61