Management Agents Events Reference

Event DescriptionEvent SeverityEvent ID
A fabric walk failed while updating the cell state. Probable Cause: Look for adjacent
chassis codes to determine the cause of FabricWalk failure. Check the backplane and
fabric connectivity. Contact the HP Support Personnel for further troubleshooting.
SNMP Trap: hpevtBootSetCellStateFabricFailure - 8983 in HPIFPTRAP.MIB.Error8983
Could not reset the cell due to failure updating cell state. Probable Cause: Most likely
a failure on the fabric or on the CC. Fabric failures should produce additional chassis
codes. If no additional chassis codes indicate the cause of the failure, then contact
the HP Support Personnel for further troubleshooting. SNMP Trap:
hpevtBootResetCellStateFailure - 8984 in HPIFPTRAP.MIB.Error8984
Table #2 Event ID numbers 9,000 through 12,863
Event DescriptionEvent SeverityEvent ID
DRAM failure on DIMM XX, deallocate rank. Probable Cause: SFW detected a failing
DIMM. Recommended Action: Replace the DIMM flagged by SFW SNMP Trap:
hpevtMemChipspareDeallocRank - 9000 in HPIFPTRAP.MIB.
Warning9000
System Clocks are not valid. Probable Cause: The Cell board has a problem. Either
the Real Time Clock is not working properly or the system is not being clocked at
the value it thinks it is. SNMP Trap: hpevtClockFreqError - 9019 in HPIFPTRAP.MIB.
Error9019
Cell Online Addition failed due to fabric access error. Probable Cause: Fabric Access
Failure,. Recommended Action: Check CC to CC link. Look for additional failure
chassis codes to provide more detail. SNMP Trap: hpevtFabricColaInitTraversableErr
- 9020 in HPIFPTRAP.MIB.
Error9020
Fabric found a bad XBC port on a reboot. Attempting to route around it. Probable
Cause: link errors. Recommended Action: Run DC Connectivity test. Check flex
cables, XBCs, and CCs. SNMP Trap: hpevtFabricAttemptFocusedReroute - 9021 in
HPIFPTRAP.MIB.
Error9021
Could not access an internal firmware table while rerouting XBC port. Probable
Cause: Firmware Error. Recommended Action: Capture chassis codes and contact
HP Support. SNMP Trap: hpevtFabricCellRerouteNinfoErr - 9022 in HPIFPTRAP.MIB.
Warning9022
Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause:
Cell hardware problem like PDH memory itself, the coherency controller, the
executing CPU or interaction between any of these cell components. Recommended
Action: Contact HP Support to troubleshoot the cell and either fix it or replace it.
SNMP Trap: hpevtBootWakeCpuIsCpuDeconfigErr - 9038 in HPIFPTRAP.MIB.
Warning9038
Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause:
Cell hardware problem like PDH memory itself, the CC chip, the executing CPU or
interaction between any of these cell components. Recommended Action: Troubleshoot
the cell and either fix it or replace it. SNMP Trap: hpevtBootWakeCpuGetCountersErr
- 9039 in HPIFPTRAP.MIB.
Warning9039
Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause:
Cell hardware problem like PDH memory itself, the CC chip, the executing CPU or
interaction between any of these cell components. Recommended Action: Troubleshoot
the cell and either fix it or replace it. SNMP Trap:
hpevtBootWakeCpuGetStructAddrErr - 9040 in HPIFPTRAP.MIB.
Warning9040
Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause:
PDC bug in which PDC thinks it was unable to safely access PDH memory when
maybe it really could have. Recommended Action: Upgrade PDC if this is found to
be the problem and a new PDC image is available. SNMP Trap:
hpevtBootCheckCpu4CompletionErr - 9041 in HPIFPTRAP.MIB.
Warning9041
Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause:
PDC bug in which PDC thinks it was unable to safely access PDH memory when
maybe it really could have. Recommended Action: Upgrade PDC if this is found to
be the problem and a new PDC image is available. SNMP Trap:
hpevtBootCheckCpuGetStructAddrErr - 9042 in HPIFPTRAP.MIB.
Warning9042
Platform Agent Events 59