Management Agents Events Reference
Event DescriptionEvent SeverityEvent ID
Couldn't determine the complex fabric topology. Probable Cause: Fabric Access Error.
Couldn't write this XBC. Recommended Action: Contact HP Support personnel to
analyze the fabric. SNMP Trap: hpevtFabricRtgCompleteTopologyErr - 8966 in
HPIFPTRAP.MIB.Error8966
Error checking a cell to cell link during traversability tests. Probable Cause: Probably
an error reading the XIN. Look for additional descriptive chassis codes. Recommended
Action: Contact HP Support personnel to check the CC SNMP Trap:
hpevtFabricRouteTraversableCc2CcErr - 8968 in HPIFPTRAP.MIB.Warning8968
An error occurred while traversing the cell to cell link. Probable Cause: Probably an
error reading the XIN. Look for additional descriptive chassis codes. Recommended
Action: Contact HP Support personnel to check the CC SNMP Trap:
hpevtFabricDataRouteTraversableCc2CcErr - 8969 in HPIFPTRAP.MIB.Warning8969
Error reading the local cell's XIN link state. Probable Cause: Hardware Access Error.
Have your HP support representative check the Coherency Controller (CC). SNMP
Trap: hpevtFabricCc2ccTraverseLclXinRdErr - 8970 in HPIFPTRAP.MIB.Warning8970
Error reading the remote cell's XIN link state register. Probable Cause: Hardware
Access Error. Have your HP support representative check the backplane and
Coherency Controller (CC). SNMP Trap: hpevtFabricCc2ccTraverseRmtXinRdErr -
8971 in HPIFPTRAP.MIB.Warning8971
The XIN link is not connected to the target cell. Probable Cause: Ensure the cells are
connected. Check historical chassis codes from most recent boot to see if the link had
ever initialized. Have your HP support representative check the backplane and
Coherency Controller (CC). SNMP Trap: hpevtFabricCc2ccTraverseLclNotInit - 8972
in HPIFPTRAP.MIB.Warning8972
The XIN link is not connected to the target cell. Probable Cause: Ensure the cells are
connected. Check historical chassis codes from most recent boot to see if the link had
ever initialized. Have your HP support representative check the backplane and
Coherency Controller (CC). SNMP Trap: hpevtFabricCc2ccTraverseRmtNotInit -
8973 in HPIFPTRAP.MIB.Warning8973
Error reading the XIN_LINK_STATE register while disabling the link. Probable
Cause: Hardware Access Error. Recommended Action: Contact HP Support personnel
to analyze the fabric, CC, Backplane. SNMP Trap: hpevtFabricDisableXinLinkReadErr
- 8974 in HPIFPTRAP.MIB.Warning8974
Error reading the XIN_LINK_STATE register. Probable Cause: link init problem.
Recommended Action: Contact HP Support personnel to check the XBC, CC,
backplane SNMP Trap: hpevtFabricXinInitRetryReadErr - 8975 in HPIFPTRAP.MIB.Error8975
Unexpected fabric firmware error. Probable Cause: An unanticipated error occurred.
Contact HP Support personnel to analyze the IPMI FPL log. SNMP Trap:
hpevtFabricAssertFabricCc - 8976 in HPIFPTRAP.MIB.Warning8976
The CPU is performance or functionally restricted. Probable Cause: A CPU is broken.
Replace it. SNMP Trap: hpevtCpuRestricted - 8979 in HPIFPTRAP.MIB.Warning8979
The RTC was found to be invalid and has been cleared. Probable Cause: The RTC
was invalid. Recommended Action: No action is required. The problem has been
corrected by SFW. SNMP Trap: hpevtPdhInvalidRtcCleared - 8981 in
HPIFPTRAP.MIB.Warning8981
Status indicates that the Late Self Tests did not actually run. Probable Cause: This
could be caused by an incompatibity problem between PAL and the CPUs. Check
that PAL supports all the CPUs installed on the system. SNMP Trap: hpevtLstNotRun
- 8982 in HPIFPTRAP.MIB.Warning8982
58 Management Agents Event Tables