Management Agents Events Reference
Event DescriptionEvent SeverityEvent ID
Error writing the XIN init disable register. Probable Cause: Check XBC, CC, backplane
SNMP Trap: hpevtFabricXinInitWriteErr - 8676 in HPIFPTRAP.MIB.Error8676
Error reading the XIN init state register. Probable Cause: Check XBC, CC, backplane
SNMP Trap: hpevtFabricXinInitReadErr - 8677 in HPIFPTRAP.MIB.Error8677
intermittent failure while retrying the CC to XBC link init. Probable Cause: contact
your HP service representative SNMP Trap: hpevtFabricLinkInitIntermittentFailure
- 8679 in HPIFPTRAP.MIB.Error8679
Initialization of a PCI node in the firmware device tree failed. Probable Cause: The
PCI component could not create a device tree node. Recommended Action: This is
an internal system firmware error. Update system firmware or contact a system
firmware representative. SNMP Trap: hpevtIodiscPciInitnodeError - 8690 in
HPIFPTRAP.MIB.Warning8690
An error was encountered while scanning the PCI bus. Probable Cause: The PCI
component experienced an internal system firmware error while scanning the PCI
bus. Recommended Action: This is an internal system firmware error. Update system
firmware or contact a system firmware representative. SNMP Trap:
hpevtIodiscPciBusscanError - 8691 in HPIFPTRAP.MIB.Error8691
An error was encountered initializing the PCI bridge. Probable Cause: The PCI
component could not initialize a P2P bridge registers, probably due to faulty
hardware. Recommended Action: Reseat or replace the PCI bridge card. SNMP Trap:
hpevtIodiscPciInitbridgeError - 8692 in HPIFPTRAP.MIB.Warning8692
An error was encountered initializing the PCI IO map. Probable Cause: The PCI
component had insufficient IO port space resources to support the installed PCI
cards. Recommended Action: Remove one or more PCI cards to reduce resource
requirements; check for faulty cards that are requesting more resources than they
need. SNMP Trap: hpevtIodiscPciIomapError - 8693 in HPIFPTRAP.MIB.Warning8693
An error was encountered creating the PCI MMIO map. Probable Cause: The PCI
component had insufficient MMIO space to support the installed cards. Recommended
Action: Remove one or more PCI cards to reduce the MMIO requirements; check for
a PCI card requesting more MMIO resources than it needs. SNMP Trap:
hpevtIodiscPciMmiomapError - 8694 in HPIFPTRAP.MIB.Warning8694
There was an error initializing the SBA node. Probable Cause: An error was while
initializing the SBA firmware structures. Recommended Action: Correct any previous
errors Invalidate NVM and reset replace the cell board SNMP Trap:
hpevtIodiscSbaInitnodeError - 8709 in HPIFPTRAP.MIB.Error8709
There was an error discovering the SBA. Probable Cause: An error was discovered
with the SBA during discovery. Recommended Action: Correct any previous errors
Replace the I/O backplane SNMP Trap: hpevtIodiscSbaDiscoverError - 8710 in
HPIFPTRAP.MIB.Error8710
An error was encountered while resetting the SBA. Probable Cause: The SBA
component could not reset one or more LBA ropes, probably due to faulty hardware.
Recommended Action: Replace the failed IO backplane. SNMP Trap:
hpevtIodiscSbaResetError - 8711 in HPIFPTRAP.MIB.Error8711
There was an error initializing the IO link. Probable Cause: The SBA IO link could
not be initialized, probably due to cable installation errors or faulty hardware.
Recommended Action: Re-install or replace the cables; replace the IO backplane.
SNMP Trap: hpevtIodiscIolinkError - 8712 in HPIFPTRAP.MIB.Warning8712
There is a problem initializing the REO cable. Probable Cause: An SBA IO cable error
has been detected. Recommended Action: Verify proper cable connection,
repair/replace the cables. SNMP Trap: hpevtIodiscCableError - 8713 in
HPIFPTRAP.MIB.Warning8713
The IO chassis discovered was powered off. Probable Cause: Connected IO chassis
is powered off. Recommended Action: Either power on the IO chassis or ignore the
error if it is powered off by design. SNMP Trap: hpevtIodiscIoChassisPower - 8714
in HPIFPTRAP.MIB.Error8714