Management Agents Events Reference
Event DescriptionEvent SeverityEvent ID
Firmware encountered an error in processing the partition variables. Probable Cause:
Either the GSP was not present or there was a resource problem storing the variable.
There should be other clues in the event id log to indicate which is the case. Restore
the GSP. SNMP Trap: hpevtPartitionVariableError - 7974 in HPIFPTRAP.MIB.Error7974
A non-critical cell power fault has occurred. Probable Cause: A power converter has
failed. Recommended Action: Contact HP Support personnel to troubleshoot the
problem SNMP Trap: hpevtCellRedundtPowerFault - 7975 in HPIFPTRAP.MIB.Error7975
CPUProcConfigValue in /options is not compatible with the current PAL/CPU.
Probable Cause: Modify CPUProcConfigValue in /options to set the correct bits.
SNMP Trap: hpevtPalProcConfigIncompatible - 8009 in HPIFPTRAP.MIB.Error8009
Firmware was unable to determine the Processor Dependent Features. Probable
Cause: Contact Engineering, This is a bug. SNMP Trap:
hpevtPalGetProcFeaturesFailed - 8010 in HPIFPTRAP.MIB.Warning8010
Data field contains data meant for firmware debug only. Probable Cause: Debug
event. Recommended Action: Contact your hp support representative. SNMP Trap:
hpevtPdhcCriticalDebug - 8127 in HPIFPTRAP.MIB.Error8127
The CLU has encountered an undefined case. Probable Cause: CLU firmware on the
UGUY has gotten into an unexpected execution path, most likely due to a hardware
issue on the UGUY. Recommended Action: Check revision of CLU firmware. If out
of date, or known bad revision, use FWUU to update CLU firmware. Contact HP
Support personnel to troubleshoot problem SNMP Trap: hpevtCluUndefinedCase -
8128 in HPIFPTRAP.MIB.Error8128
An unknown Cell voltage margin has been detected. Probable Cause: A user has
manually, using back-door debugging methods, altered the voltage margin setting
of one or more Cell Board or Cell Power Board converters. SNMP Trap:
hpevtCellVoltageMarginUnkn - 8130 in HPIFPTRAP.MIB.Warning8130
The run-time verification of a programming assumption has failed. Probable Cause:
Hardware or software in unknown state. Recommended Action: Upgrade PDHC
firmware to latest revision. If already at current revision, contact HP Support
personnel to troubleshoot the problem. SNMP Trap: hpevtPdhcAssertionFailed -
8131 in HPIFPTRAP.MIB.Warning8131
An unknown error has been detected by the PDHC firmware. Probable Cause:
Hardware in unknown state, or programming bug found. Recommended Action:.
Recommended Action: Upgrade PDHC firmware to latest revision. If already at
current revision, contact HP support personnel to troubleshoot the problem. SNMP
Trap: hpevtPdhcFirmwareUnknownErr - 8132 in HPIFPTRAP.MIB.Warning8132
An attempt to write to a device on the PDHCs I2C bus has failed. Probable Cause:
A hardware fault has occurred. Recommended Action: Contact HP Support personnel
to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. SNMP
Trap: hpevtPdhcI2cWriteFailed - 8133 in HPIFPTRAP.MIB.Warning8133
An attempt to read from a device on the PDHC's I2C bus has failed. Probable Cause:
A hardware fault has occurred. Recommended Action: Contact HP Support personnel
to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. SNMP
Trap: hpevtPdhcI2cReadFailed - 8134 in HPIFPTRAP.MIB.Warning8134
An attempt to write to a device on the PDHC's SM bus has failed. Probable Cause:
A hardware fault has occurred. Recommended Action: Contact HP Support personnel
to troubleshoot the Cell Board, Cell Power Board, and/or PDH Daughtercard. SNMP
Trap: hpevtPdhcSmbusWriteFailed - 8135 in HPIFPTRAP.MIB.Warning8135
An attempt to read from a device on the PDHC's SM bus has failed. Probable Cause:
A hardware fault has occurred. Recommended Action: Contact HP Support personnel
to troubleshoot the Cell Board, Cell Power Board, and PDH Daughtercard. SNMP
Trap: hpevtPdhcSmbusReadFailed - 8136 in HPIFPTRAP.MIB.Warning8136