Management Agents Events Reference
Event DescriptionEvent SeverityEvent ID
A XBC port was unexpectedly found to be landmined. Probable Cause: No action
required. SNMP Trap: hpevtXbcPortLandmined - 5799 in HPIFPTRAP.MIB.Error5799
CPUs running at different speeds were detected during rendezvous. Probable Cause:
Reconfigure the PD so that all cells have processors running at the same speed. SNMP
Trap: hpevtPdIncompatibleCpuSpeeds - 5800 in HPIFPTRAP.MIB.Error5800
The link between the local CC and the local XBC is unexpectedly not initialized.
Probable Cause: An error initializing fabric. Recommended Action: A previously
reported event may provide exact detailsReboot, if failure persists, then either replace
the CC chip or the system backplane. SNMP Trap: hpevtFabricCellLinkNotInit - 5802
in HPIFPTRAP.MIB.Error5802
An invalid XBC number was given. Probable Cause: Firmware error. Recommended
Action: Reset cell SNMP Trap: hpevtFabricInvalidXbcNum - 5803 in HPIFPTRAP.MIB.Error5803
An invalid XBC port number was given. Probable Cause: Firmware error.
Recommended Action: Reset cell SNMP Trap: hpevtFabricInvalidXbcPortNum - 5804
in HPIFPTRAP.MIB.Error5804
A bad parameter was passed to the LED function in the utilities component. Probable
Cause: Contact FW engineering. This is a bug. SNMP Trap:
hpevtUtilitiesLedParamError - 5805 in HPIFPTRAP.MIB.Warning5805
An unexpected neighbor type was read from a XBC PORT_NEIGHBOR_INFO CSR.
Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset
cell. SNMP Trap: hpevtFabricUnexpectedNtype - 5806 in HPIFPTRAP.MIB.Error5806
A given XBC port is not a valid XBC-CC port. Probable Cause: Firmware error.
Recommended Action: Reset cell SNMP Trap: hpevtFabricPortNotCc - 5807 in
HPIFPTRAP.MIB.Error5807
A XBC port was unexpectedly found to be an invalid XBC-XBC port. Probable Cause:
Firmware error. Recommended Action: Reset cell. SNMP Trap:
hpevtFabricPortNotXbc - 5808 in HPIFPTRAP.MIB.Error5808
The XBC neighbor chip number does not match the expected value for this topology.
Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset
cell. SNMP Trap: hpevtFabricUnexpectedNChip - 5809 in HPIFPTRAP.MIB.Error5809
The XBC neighbor port number does not match the expected value for this topology.
Probable Cause: Bad connection between XBC and cell. Recommended Action: Reset
cell. SNMP Trap: hpevtFabricUnexpectedNPort - 5810 in HPIFPTRAP.MIB.Error5810
Write through to BMC token failed. Probable Cause: Problem accessing the BMC.
Recommended Action: Reset BMC or reboot. Upgrade BMC FW and System FW. If
problem persists, contact your HP representative for support. SNMP Trap:
hpevtBootNvmWriteToBmcTokenFailure - 5811 in HPIFPTRAP.MIB.Warning5811
Utilities reported an error while trying to manipulate the LED. Probable Cause: It is
likely the GSP is not present or the device specified is not present. Solve these
problems and try again. SNMP Trap: hpevtUtilitiesLedError - 5812 in
HPIFPTRAP.MIB.Warning5812
Duplicate Cpu Ids were detected within a cell. Probable Cause: Most likely cause is
a bad cpu module connection on the cell board. Replace the cell board. SNMP Trap:
hpevtDuplicateCpuIds - 5813 in HPIFPTRAP.MIB.Error5813
OS crashdump started (D700). Probable Cause: panic occurred SNMP Trap:
hpevtHp-uxCrashdumpStarted - 5823 in HPIFPTRAP.MIB.Warning5823
OS legacy PA hex fault code (Bxxx). Probable Cause: fault/panic SNMP Trap:
hpevtHp-uxHexFaultCode - 5824 in HPIFPTRAP.MIB.Error5824
OS dump status (EFxx). Probable Cause: panic, mca, or INIT path: attempt to write
out the dump is complete. Recommended Action: No action required SNMP Trap:
hpevtHp-uxDumpStatus - 5825 in HPIFPTRAP.MIB.Warning5825
Platform Agent Events 37