Management Agents Events Reference
Event DescriptionEvent SeverityEvent ID
Prototype CPU installed. Probable Cause: A Prototype CPU is installed. Recommended
Action: Replace CPU with a production CPU. SNMP Trap:
hpevtBootProtoTypeCpuInstalled - 5744 in HPIFPTRAP.MIB.Warning5744
final boot rendezvous monarch watchdog timeout. Probable Cause: A watchdog
timer has expired and determined that a monarch is dead. Recommended Action:
Reboot, if problem persists, replace CPU. SNMP Trap:
hpevtBootFinalRendezWatchdogFail - 5745 in HPIFPTRAP.MIB.Warning5745
Supplemental cpu tests generated an unexpected result. Probable Cause: A CPU
failed supplemental selftests. Replace the offending CPU. SNMP Trap:
hpevtCpuSupplementalTestFailed - 5746 in HPIFPTRAP.MIB.Error5746
A multi-bit error was found while reading a XBC CSR. Probable Cause: Possibly bad
link or cell connection. Recommended Action: Reset partition, and check hardware
associated with event data. SNMP Trap: hpevtFabricReadMbeError - 5747 in
HPIFPTRAP.MIB.Warning5747
The return value from a function was an unknown value. Probable Cause: Firmware
error. Recommended Action: Reset cell SNMP Trap: hpevtFabricUnexpectedStatus
- 5749 in HPIFPTRAP.MIB.Warning5749
Cannot get system ID status from BMC. Probable Cause: Inaccessible FRU EPROM
on system board and/or I/O backplane. Failure in IPMI messaging path on system
board and/or I/O backplane. Recommended Action: Check FRU EPROM content and
accessibility on system and I/O backplane using ifru. If BMC communication is not
working (no answer from BMC), flash BMC firmware. If it cannot be done or doesn't
solve the problem, replace system board. If system board FRU EPROM cannot be
accessed, replace system board If I/O backplane FRU EPROM cannot be accessed,
replace I/O backplane SNMP Trap: hpevtEfiSysidBmcWarning - 5750 in
HPIFPTRAP.MIB.Warning5750
Cannot read a system ID. Probable Cause: BMC failure. Recommended Action:
Unplug power from the system for 10 seconds and try rebooting the system. SNMP
Trap: hpevtEfiSysidBmcReadError - 5751 in HPIFPTRAP.MIB.Warning5751
Failed to write new system ID. BMC reported an error. Probable Cause:
Communication failure with the BMC. Recommended Action: Unplug power from
the system for 10 seconds and try rebooting the system. SNMP Trap:
hpevtEfiSysidBmcWriteError - 5752 in HPIFPTRAP.MIB.Warning5752
The system ID(s) currently in the system is invalid. Probable Cause: The system ID(s)
is invalid and the user did not elect to fix the problem. Recommended Action: Reboot
the system and follow the prompts to fix the issue. SNMP Trap: hpevtEfiSysidInvalid
- 5753 in HPIFPTRAP.MIB.Warning5753
EFI unable to find the SAL services for installing interrupt handlers. Probable Cause:
Corrupted ESI table. Recommended Action: Reboot system. SNMP Trap:
hpevtEfiRtIvtEsiTableErr - 5755 in HPIFPTRAP.MIB.Error5755
EFI unable to find the SAL service to install run-time interrupt handlers. Probable
Cause: Mismatch between EFI and SAL. Recommended Action: Upgrade system
firmware. SNMP Trap: hpevtEfiRtIvtEsiQueryErr - 5756 in HPIFPTRAP.MIB.Error5756
EFI unable to find the SAL services for installing interrupt handlers. Probable Cause:
Mismatch between EFI and SAL portions of the system firmware. Recommended
Action: Reboot, if problem persists, contact your HP representative for support.
SNMP Trap: hpevtEfiBootIvtEsiTableErr - 5757 in HPIFPTRAP.MIB.Error5757
EFI unable to find the SAL service to install boot-time interrupt handlers. Probable
Cause: Mismatch between EFI and SAL. Recommended Action: Reboot or upgrade
system firmware. If problem persists contact your HP representative for support.
SNMP Trap: hpevtEfiBootIvtEsiQueryErr - 5758 in HPIFPTRAP.MIB.Error5758
Too many parameters were passed to the utilities system. Probable Cause: This is a
firmware error. Contact FW engineering. SNMP Trap: hpevtUtilitiesParmListTooLarge
- 5760 in HPIFPTRAP.MIB.Warning5760