Management Agents Events Reference
Event DescriptionEvent SeverityEvent ID
EFI internal error detected resulting in execution of ASSERT macro. Probable Cause:
The cause is unknown. Recommended Action: Look at previous events and ASCII
information in this event for more information. If problem persists, contact HP support
to troubleshoot the problem. SNMP Trap: hpevtEfiAssertError - 5712 in
HPIFPTRAP.MIB.Warning5712
EFI has executed the 'break' shell command. Probable Cause: Executing the 'break'
command. Recommended Action: Check for user entering 'break' command. Check
for shell scripts using the 'break' command. SNMP Trap: hpevtEfiEfiBreakpoint -
5713 in HPIFPTRAP.MIB.Error5713
EFI USB HCD interrupt service has detected the host controller is hung. Probable
Cause: Problem with USB controller. Recommended Action: Reset the card containing
the USB interface to restart the controller. Contact your HP representative to check
the USB interface. SNMP Trap: hpevtEfiHcdHostHung - 5714 in HPIFPTRAP.MIB.Error5714
The EFI/SAL handoff structure's version does not match EFI expectations. Probable
Cause: EFI/SAL firmware mismatch. Recommended Action: Reboot. If problem
persists contact your HP representative for support. SNMP Trap:
hpevtEfiSalHandoffVerMismatch - 5715 in HPIFPTRAP.MIB.Error5715
Unable to obtain access to all RTC SAL services. Probable Cause: Not all expected
services are available. Mismatch between EFI and SAL versions. Internal EFI error.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. SNMP Trap: hpevtEfiSalRtcServiceNotInit - 5717 in HPIFPTRAP.MIB.Error5717
Unable to obtain access to all SAL timer services. Probable Cause: Not all expected
services are available. Mismatch between EFI and SAL versions. Internal EFI error.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. SNMP Trap: hpevtEfiSalTimerServiceNotInit - 5718 in HPIFPTRAP.MIB.Error5718
EFI unable to start the periodic timer. Probable Cause: Internal system firmware
error. Recommended Action: Reboot. If problem persists contact your HP
representative for support. SNMP Trap: hpevtEfiSalStarttimerServiceNotInit - 5719
in HPIFPTRAP.MIB.Error5719
No I/O port space region found in the MDT. Probable Cause: EFI/SAL handoff
structure corrupted. Recommended Action: Reboot. If problem persists contact your
HP representative for support. SNMP Trap: hpevtEfiNoIoPortSpaceRegionFound -
5720 in HPIFPTRAP.MIB.Error5720
EFI reached an unimplemented section of code. Probable Cause: Reached
unimplemented firmware. Recommended Action: Upgrade system firmware. SNMP
Trap: hpevtEfiBreakpoint - 5721 in HPIFPTRAP.MIB.Error5721
EFI unable to read current speedy boot settings. Probable Cause: BMC not functioning
properly. Recommended Action: Reset the BMC. Contact your HP representative to
check the BMC. SNMP Trap: hpevtEfiSpeedyBootTokenNotRead - 5722 in
HPIFPTRAP.MIB.Warning5722
Unpermitted SAL callback attempted. Probable Cause: Internal EFI error.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. SNMP Trap: hpevtEfiSalCallbackAttempted - 5723 in HPIFPTRAP.MIB.Error5723
EFI unable to determine frequency base of the CPU interval timer. Probable Cause:
Invalid timer ratio. Recommended Action: Reset system. SNMP Trap:
hpevtEfiSalFreqBaseUnknown - 5724 in HPIFPTRAP.MIB.Warning5724
EFI system events already initialized. Probable Cause: Multiple attempts to initialize
system events, EFI internal error. Recommended Action: Upgrade system firmware.
If problem persists, contact HP support to troubleshoot the problem. SNMP Trap:
hpevtEfiSysEventAlreadyInit - 5725 in HPIFPTRAP.MIB.Warning5725
Unable to create internal virtualization event while initializing IPMI events. Probable
Cause: Out of resources. Internal EFI error. Recommended Action: Reboot system.
Upgrade system firmware. SNMP Trap: hpevtEfiSysEventCreateEventFail - 5726 in
HPIFPTRAP.MIB.Warning5726
32 Management Agents Event Tables